CONTROL CABLES / POWER CABLES

PVC insulated Control Cable upto 100 Cores and 650/1100 V grade armoured or unarmoured as per IS 1554 Part I/BS 6346.

Available with Insulation
XLPE - HR PVC
Inner & Outer Sheath
HR PVC, FRLS PVC, FR PVC

"UDEYPYRO" 1.1 KV Annealed high conuctivity solid copper conductor, 1.5 Sq.mm. PVC insulated, Inner Sheathed, Armoured/Unarmoured & PVC Sheathed Control Cables conforming to
IS : 1554 (part-I) amended upto date / BS 6346
Numer of Cores Nominal thickness of Insulation Min. thickness of Inner sheath ARMOUR Nominal thickness of Outer Sheath Approx. overall diameter Approx. weight of cable Max. DC coductor resistance at 20oC CURRENT RATINGS
Gatv. Round Steel Wire Nominal diameter Gatv. Round Steel Strip Nominal thickness Unarmoured armoured Unarmoured armoured Unarmoured armoured Direct In Ground In Ducts In air
No. mm mm mm mm mm mm mm mm Kg/Km Kg/Km Ohm/Km Amps Amps Amps
2 0.8 0.3 1.4 - 1.8 1.8 10.4 13.6 167 440 12.1 23 20 20
3 0.8 0.3 1.4 - 1.8 1.8 1094 14.1 200 478 12.1 21 17 17
4 0.8 0.3 1.4 - 1.8 1.8 11.7 14.9 230 526 12.1 21 17 17
5 0.8 0.3 1.4 - 1.8 1.8 12.6 15.7 250 630 12.1 21 17 17
6 0.8 0.3 1.4 - 1.8 1.8 13.4 16.6 300 675 12.1 15 13 13
7 0.8 0.3 1.4 - 1.8 1.8 13.4 16.6 320 690 12.1 14 13 13
10 0.8 0.3 - 0.8 1.8 2.0 16.5 19.2 430 810 12.1 13 11 11
12 0.8 0.3 - 0.8 1.8 2.0 17.0 19.7 450 870 12.1 11 10 10
14 0.8 0.3 - 0.8 1.8 2.0 17.7 20.4 510 968 12.1 11 9 9
16 0.8 0.3 - 0.8 2.0 2.0 19.0 21.3 620 1068 12.1 11 9 9
19 0.8 0.3 - 0.8 2.0 2.0 19.9 22.2 660 1155 12.1 10 9 9
24 0.8 0.3 - 0.8 2.0 2.0 23.0 25.3 820 1300 12.1 9 8 8
30 0.8 0.3 - 0.8 2.0 2.0 24.2 26.5 980 1550 12.1 9 7 7
37 0.8 0.3 - 0.8 2.0 2.0 26.3 28.3 1200 1765 12.1 8 7 7
61 0.8 0.4 - 0.8 2.2 2.2 32.7 34.8 1850 2400 12.1 7 6 6
"UDEYPYRO" 1.1 KV Annealed high conuctivity solid copper conductor, 2.5 Sq.mm. PVC insulated, Inner Sheathed, Armoured/Unarmoured & PVC Sheathed Control Cables conforming to
IS : 1554 (part-I) amended upto date
Numer of Cores Nominal thickness of Insulation Min. thickness of Inner sheath ARMOUR Nominal thickness of Outer Sheath Approx. overall diameter Approx. weight of cable Max. DC coductor resistance at 20oC CURRENT RATINGS
Gatv. Round Steel Wire Nominal diameter Gatv. Round Steel Strip Nominal thickness Unarmoured armoured Unarmoured armoured Unarmoured armoured Direct In Ground In Ducts In air
No. mm mm mm mm mm mm mm mm Kg/Km Kg/Km Ohm/Km Amps Amps Amps
2 0.9 0.3 1.4 - 1.8 1.8 11.6 14.8 215 504 7.41 32 27 27
3 0.9 0.3 1.4 - 1.8 1.8 12.2 15.4 247 560 7.41 27 24 24
4 0.9 0.3 1.4 - 1.8 1.8 13.1 16.3 285 625 7.41 27 24 24
5 0.9 0.3 1.4 - 1.8 1.8 14.2 17.4 370 730 7.41 27 24 24
6 0.9 0.3 1.4 - 1.8 1.8 15.2 18.4 400 820 7.41 20 18 18
7 0.9 0.3 1.4 - 1.8 1.8 15.2 18.4 410 860 7.41 20 17 17
10 0.9 0.3 - 0.8 2.0 2.0 19.3 21.6 580 900 7.41 18 15 15
12 0.9 0.3 - 0.8 2.0 2.0 19.8 22.1 650 1000 7.41 17 14 14
14 0.9 0.3 - 0.8 2.0 2.0 20.8 23.1 740 1150 7.41 16 13 13
16 0.9 0.3 - 0.8 2.0 2.0 21.9 24.2 840 1210 7.41 15 13 13
19 0.9 0.3 - 0.8 2.0 2.0 22.9 25.2 950 1400 7.41 14 12 12
24 0.9 0.3 - 0.8 2.0 2.0 26.6 28.9 1200 1700 7.41 13 11 11
30 0.9 0.3 - 0.8 2.0 2.2 28.1 30.8 1450 1950 7.41 12 10 10
37 0.9 0.4 - 0.8 2.2 2.2 30.8 32.9 1800 2250 7.41 11 10 10
61 0.9 0.4 - 0.8 2.2 2.4 38.1 40.6 2700 3400 7.41 9 8 8